SEIKOM Electronic - TÜV-certified quality for over 30 years. Trust in our experience.

30 years of experience | TÜV-tested quality | ISO9001-certified | Shipping within 24 hours | Contact us now

New whitepaper
Now available: Free white paper on our latest measurement and control technologies!
Download here!

HumiGuard® HT210 - Industrial humidity and temperature transmitter, duct or wall-mounted version, can be combined with S-probes, interchangeable probes, MODBUS

Sku: 1429/K/D

Description

  • Reliable and precise measurement technology for optimum measurement of humidity and temperature
  • MODBUS connection
  • Optionally available as a compact device or with remote sensor
  • Versatile application areas due to use in areas up to 200°C (depending on probe - available separately)
  • Robust design: IP65
Design
Display
€246,54
Shipment is calculated in the checkout.
Lieferzeit Symbol Delivery time: Available in 1-2 weeks

specification

  • Medium
    Air, non-aggressive
  • Device type
    Humidity and temperature transmitter, Sensors for humidity and temperature for digital data transmission RS485 / MODBUS-RTU, Output of the humidity-dependent variables of the hx diagram and temperature
  • Device design
    Compact/channel version, Wall version, two-part with remote probe, interchangeable probes
  • Temperature range
    depending on probe: -80 ... 200°C
  • Temperature accuracy
    depending on probe: -80 ... 200°C
  • Medium temperature
    -80 ... 200°C
  • Relative humidity range
    0 ... 100% rH
  • Relative humidity accuracy
    10 ... 90% rH at 23°C: ±1.5% rH, <10% rF oder >90% rH: ±2% rH, Temperature influence ҂ 23°C: <0.02% RH/K
  • Display
    Display optional, 2 lines, 3 digits + 1 decimal place, Display rel. humidity and temperature
  • Protection class evaluation unit
    IP65
  • Protection class sensor
    IP65
  • Protection class housing
    IP65
  • Special features
    up to 200°C, Modbus, hx sizes, Display optional, Probes available in ammonia-resistant and pressure-resistant
  • Output signal
    Digital output
  • Immersion depth
    Sensor-dependent
  • Housing material
    Die-cast aluminum
  • Sensor material
    Stainless steel
  • Pressure resistance
    Sensor-dependent up to 25 bar
  • Housing dimensions
    80 mm x 75 mm x 57 mm
  • Diameter
    Ø15 mm
  • Power supply
    10 ... 30 V DC
  • Electrical connection
    Cable gland: clamping range Ø3 ... 7mm, screw terminals
  • Max. power consumption
    Intrinsic power consumption Transmitter: <0.88 mA, Intrinsic current consumption transmitter + probe: <1.95 mA, Intrinsic current consumption transmitter + probe + display: < 2.10 mA
  • Recommended cable cross-section
    max. 1.5 mm²
  • Response time
    at v=2 m/s: <10 s
  • Switching differential
    Hyteresis: <1% RH
  • Sensor element type
    FE09, Pt1000 1/3-DIN Kl.B
  • Ambient temperature
    -40 ... 85°C
  • Storage temperature
    -40 ... 85°C
  • Certificates
    CE
  • Country of origin
    Germany
  • Customs tariff number
    90 26 20 20
  • HS code
    90 26 20

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

HumiGuard® HT210 - Industrial humidity and temperature transmitter, duct or wall-mounted version, can be combined with S-probes, interchangeable probes, MODBUS

Away €157,50

Medium

Air, non-aggressive

Device type

Humidity and temperature transmitter, Sensors for humidity and temperature for digital data transmission RS485 / MODBUS-RTU, Output of the humidity-dependent variables of the hx diagram and temperature

Device design

Compact/channel version, Wall version, two-part with remote probe, interchangeable probes

Temperature range

depending on probe: -80 ... 200°C

Temperature accuracy

depending on probe: -80 ... 200°C

Flow range

Flow accuracy

Medium temperature

-80 ... 200°C

Relative pressure range

Relative pressure accuracy

Atmospheric pressure range

Atmospheric pressure accuracy

Measured variable

Differential pressure range

Differential pressure accuracy

VOC range

VOC accuracy

CO₂ range

CO₂ accuracy

Relative humidity range

0 ... 100% rH

Relative humidity accuracy

10 ... 90% rH at 23°C: ±1.5% rH, <10% rF oder >90% rH: ±2% rH, Temperature influence ҂ 23°C: <0.02% RH/K

Number of differential pressure ranges

Maximum measuring range limit

Display

Display optional, 2 lines, 3 digits + 1 decimal place, Display rel. humidity and temperature

Switching point

Protection class evaluation unit

IP65

Protection class sensor

IP65

Protection class housing

IP65

Special features

up to 200°C, Modbus, hx sizes, Display optional, Probes available in ammonia-resistant and pressure-resistant

Cable length

IK impact resistance rating

Luminous flux

Emergency luminous flux

Efficiency

Light color

Color rendering index CRI

Flicker factor

Power factor

Humidity resolution

Temperature resolution

Max. differential pressure

Adjustment range

product.metafields.custom.messgroesse1

Output signal

Digital output

Analog output specification

Switching output specification

Digital output specification

Sensor break output signal

Sensor short-circuit output signal

Analog input

Digital input

Relay output specification

Immersion depth

Sensor-dependent

Process connection

Housing material

Die-cast aluminum

Connection head material

Sensor material

Stainless steel

Pressure resistance

Sensor-dependent up to 25 bar

Overpressure limit

Weight

Operating pressure

Housing dimensions

80 mm x 75 mm x 57 mm

Mounting

Minimum pipe diameter

Fastening strap specification

Burst pressure

Vacuum resistance

Dimensions

Cable gland

Diameter

Ø15 mm

Installation depth

Front cover material

Sensor response length

Capillary tube length

Max. pressure

Power supply

10 ... 30 V DC

Electrical connection

Cable gland: clamping range Ø3 ... 7mm, screw terminals

Max. power consumption

Intrinsic power consumption Transmitter: <0.88 mA, Intrinsic current consumption transmitter + probe: <1.95 mA, Intrinsic current consumption transmitter + probe + display: < 2.10 mA

Power

Recommended cable cross-section

max. 1.5 mm²

Load resistance

Insulation resistance

Current and contact rating

Response time

at v=2 m/s: <10 s

Minimum switching capacity

Protection class

Min. output power

Self-consumption

product.metafields.custom.leistung Bürde max.

Max. input current

Measuring resistor

Switching differential

Hyteresis: <1% RH

Overvoltage category

Reverse polarity protection

Supply output

Sensor element type

FE09, Pt1000 1/3-DIN Kl.B

Ambient temperature

-40 ... 85°C

Storage temperature

-40 ... 85°C

Ambient humidity

Ambient pressure

Temperature compensation

Optimal inlet path

Optimal outlet path

Temperature gradient

Certificates

CE

ATEX certification

SIL level

Country of origin

Germany

Customs tariff number

90 26 20 20

HS code

90 26 20

Warranty

Service life

Fire protection

Alarm

Lining

Color

Output signal accuracy LCD/Modbus

Manufacturer

Notes

Hysteresis

Conformity

Long-term stability

Material contact

Media compatibility

Emergency light

Certification mark

Signal output reproducibility

Switching function (flow)

Fuse

Wet bulb temperature spec.

Dew point temperature spec.

Absolute humidity spec.

Availability

Pollution degree

Heat dissipation

Repeatability

Permissible air velocity

Internal thread

External thread

Wrench size

Inner diameter

Accessories

Show product

Welcome to Shopify Store

I act like: