In zahlreichen industriellen Prozessen ist die präzise Überwachung, Messung und Steuerung der Strömung mittels Durchflussmessgeräte von Flüssigkeiten und Gasen von entscheidender Bedeutung. Ob im Maschinen- und Anlagenbau, in der Chemie, verarbeitenden Industrie, Energieerzeugung oder Wasserwirtschaft – viele Branchen sind auf zuverlässige Ergebnisse einer genauen Durchflussüberwachung und -messung angewiesen.

Welcome to Shopify Store

I act like:

View as

Bei SEIKOM Electronic verfügen wir über jahrzehntelange Expertise auf dem Gebiet der Strömungsmessung. Unsere Produkte basieren auf den Prinzipien qualitativer Verarbeitung und wertvollen Erfahrungswerten aus der Industrie. Wir bieten unseren Kunden das passende Equipment für eine präzise Durchflussmessung.

Strömungsmessung als Erfolgsfaktor

Die Durchflussmessung mittels eines Durchflussmessgeräts ist ein wichtiger Prozess in verschiedenen Industriezweigen und bei technischen Anwendungen. Das Volumen oder die Menge von Flüssigkeiten oder Gasen, die innerhalb eines bestimmten Zeitraums an einem Punkt vorbeiströmen, werden dabei quantitativ bestimmt.

Es existieren unterschiedliche Arten von Durchflussmessungen, die auf verschiedenen physikalischen Prinzipien aufbauen. Wir von SEIKOM Electronic setzen bei unserer Mess- und Regeltechnik in erster Linie auf die kalorimetrische bzw. thermische Strömungsmessung. Hierbei messen zum Teil beheizte Sensoren die Umgebungstemperatur. Durch vorbeifließende Medien wie Gase oder Flüssigkeiten wird Wärme an den Sensoren abgetragen. Auf Basis dieses Temperaturabfalls wird dank der Durchflussmessgeräte die Menge des vorbeifließenden Mediums zuverlässig ermittelt. Da sich neben der Strömung auch die Medientemperatur verändern kann, findet stets eine Referenzmessung statt, um eine gleichbleibend hohe Messqualität zu gewährleisten.

Durchflussmessgeräte – effiziente Durchflussüberwachung

Für die präzise Durchflussmessung sind spezielle Geräte erforderlich. SEIKOM Electronic bietet Ihnen eine Reihe hochwertiger Durchflussmessgeräte, von einfachen Strömungswächtern und Strömungsmessgeräten bis zu präzisen Volumenstrommessgeräten. Alle Durchflussmessgeräte sind konzipiert für eine exakte und zuverlässige Strömungsmessung in anspruchsvollen industriellen Umgebungen.

In unserem Sortiment verfügen wir über verschiedene Modelle an thermischen Strömungsmessgeräten, die auf unterschiedlichen Technologien basieren und den Anforderungen verschiedener Umgebungen entsprechen:

·        Durchflussmessung von Gasen

·        Durchflussmesser für Wasser

·        Volumenstrom messen

·        Strömungswächter ATEX – Schutz in Explosionszonen

·        Strömungswächter SIL  – zertifizierte Risikoreduktion

 

Unsere Durchflussmessgeräte unterliegen in unserer Entwicklung strengen Kriterien, um genaue und zuverlässige Ergebnisse zu liefern. Dazu gehören eine hohe Sensibilität, eine schnelle Reaktionszeit, eine geringe Druckabhängigkeit und eine minimale Störanfälligkeit gegenüber Temperaturschwankungen.

Die Vorteile der Durchflussmessgeräte von SEIKOM Electronic

Unsere innovativen Lösungen sind darauf ausgerichtet, präzise Durchflussdaten zu liefern und somit Ihre Prozesse sicher zu gestalten und zu optimieren. Die Durchflussmessgeräte von SEIKOM Electronics bieten Ihnen deshalb viele Vorteile:

·        Mittels Durchflussmessung über unsere Messgeräte überwachen Sie zuverlässig die Strömung. In einem System verfolgen Sie den Durchfluss in Echtzeit und können sicherstellen, dass dieser den gewünschten Parametern entspricht.

·        Ebenso wird die Einhaltung von Umweltauflagen durch die Kontrolle via Durchflussmengenmesser gewährleistet. Diese Methode bietet eine zuverlässige Möglichkeit, sicherzustellen, dass Abwasser- oder Abluftströme den gesetzlichen Vorschriften und Umweltstandards entsprechen.

·        Dank unserer Durchflussmessgeräte erhalten Sie genaue Ergebnisse für eine sorgfältige und permanente Kontrolle. Dadurch haben Sie die Möglichkeit, unmittelbar auf eventuelle Veränderungen zu reagieren.

·        Mithilfe unserer Systeme zur Strömungsmessung steigern Sie spürbar die Effizienz, da Abweichungen vom Optimum direkt erkannt werden. Durch die kontinuierliche Überwachung des Durchflusses können Betreiber Prozessabläufe optimieren, Energieeffizienz steigern und unerwartete Ausfälle verhindern.

·        Der anhaltende Optimierungsprozess als Folge der Durchflussmessung kann zu deutlichen Kosteneinsparungen führen. Durch die permanente Strömungsüberwachung und gegebenenfalls Anpassung des Durchflusses werden unnötige Ressourcenverschwendungen vermieden.

·        Aufgrund der robusten Bauweise sind unsere Durchflussmessgeräte von SEIKOM Electronic sehr langlebig. Die Durchflussmessgeräte sind so konstruiert, dass sie extremen Bedingungen in verschiedenen Umgebungen standhalten.

·        Durch den Verzicht auf bewegliche Teile sind unsere Durchflussmessgeräte zudem besonders wartungsarm. Dadurch sparen Sie ebenfalls wertvolle Zeit und Kosten.

 

Steigern Sie Ihre Effizienz und Sicherheit mit den Durchflussmessgeräten von SEIKOM Electronic und behalten Sie so Ihre Daten zuverlässig im Blick. Darüber hinaus können Sie sich bei uns selbstverständlich auch auf eine kontinuierliche Weiterentwicklung verlassen. Auf Wunsch entwickeln wir eine spezifische Lösung für Ihren Anwendungsbereich.

 

Strömungsmessung – welches Durchflussmessgerät ist das richtige?

Die richtige Wahl Ihres Durchflussmessgeräts ist von entscheidender Bedeutung, da sie maßgeblich die Genauigkeit und Zuverlässigkeit der erfassten Daten beeinflusst. Neben den Umgebungsbedingungen, in denen die Messung durchgeführt wird, müssen auch die spezifischen Anforderungen des Prozesses oder der Anwendung berücksichtigt werden. Dazu gehören Aspekte wie der Messbereich, die Temperatur und der Druck des zu messenden Mediums. Darüber hinaus spielt die Art des Mediums eine wesentliche Rolle: Unterschiedliche Flüssigkeiten oder Gase weisen unterschiedliche physikalische Eigenschaften auf, die sich auf die Wahl des Durchflussmessgeräts auswirken. Die Integration des Messgeräts in das bestehende Steuerungs- oder Überwachungssystem ist ein weiterer zu beachtender Punkt. Die Kommunikationsschnittstellen und Protokolle müssen kompatibel sein, um eine nahtlose Integration zu gewährleisten.

Haben Sie noch weitere Fragen? Oder legen Sie Wert auf eine ausführliche und persönliche Beratung für Ihre Durchflussmessung? Dann treten Sie mit uns in Kontakt , wir freuen uns auf Ihre Anfrage!


 

Frequently asked questions

WHICH MEDIUM (E.G. GASES, LIQUIDS) SHOULD BE MEASURED DURING THE FLOW MEASUREMENT?

Depending on the medium being measured, different sensors and materials are used - the underlying thermal measuring principle is the same. When measuring air/gases, the sensor elements are usually located directly in the air flow and can reliably monitor the smallest changes in flow. We use a closed sensor system for monitoring liquid media.

WHICH MEDIA TEMPERATURE SHOULD BE MEASURED?

All measuring devices can be used for flow measurement in industrial environments up to approx. 80°C without any problems. We also offer sensors for hot environments up to 400°C. We use special sensor elements for these media temperatures. These have proven themselves in particular in the field of industrial furnaces, heating equipment, heating registers, soldering systems as well as testing and inspection equipment, in mechanical and plant engineering, process technology, exhaust gas and emission monitoring.

WHICH SIGNAL OUTPUT IS REQUIRED?


SEIKOM Electronic offers flowmeters with various signal outputs, including relay outputs and relative as well as linear analog outputs (0-10 V, 4-20 mA).

Relay outputs enable the monitoring of minimum or maximum currents by triggering a switching contact when specified values are exceeded or not reached. They are ideal for air flow monitoring in air ducts and machines. Examples of devices are RLSW4 to RLSW8 and NLSW45-3.

Relative analogue outputs provide linearized output signals for visualizing the flow level and are often used in programmable logic controllers (PLC, PLC, DDC), such as models RLSW4A and RLSW5A.

Linear analog outputs provide the most accurate flow measurement and processing for controllers and fan controls, such as the RLSW8.

These flow meters are designed for various applications in flow monitoring and control, providing reliable and accurate measurements for different requirements.

WHAT TYPE OF SENSOR IS REQUIRED?

Devices for flow measurement are available both in a compact design (RLSW®) and as an evaluation unit for installation in a control cabinet (NLSW®) with a separate sensor.

In the compact design (RLSW®), the sensor and evaluation electronics form a single unit and the flow measurement and signal evaluation take place directly at the measuring point. The measuring devices are designed for robust industrial use and generally have an IP65 degree of protection (RLSW®8: IP54). The advantages of this design are, on the one hand, the ability to read information directly at the installation location (LED or LCD display). Secondly, signals are evaluated immediately and then transmitted over longer distances by cable.

The design with evaluation unit (NLSW®) and separate wired sensor is suitable for control cabinet installation. This design is particularly suitable for harsh process applications and if the signals are to be processed directly in the control cabinet. It is also essential for flow measurement in explosion-protected environments (ATEX zones 1 and 2).

If you have opted for a separate evaluation unit, please note that the corresponding sensor (available in different lengths/immersion depths) is available separately.

All sensors have a standard cable length of 2.5 meters. We are happy to manufacture sensors with longer cable connections (up to 30 m in environments up to 80°C) - simply contact our team.

ARE THERE DEVICES SPECIFICALLY FOR THE REQUIREMENTS OF EXPLOSION-PROOF AREAS OR SAFETY REQUIREMENTS SUCH AS SIL?

For explosion-protected areas, we use specially certified sensors and evaluation units for ATEX zones 1 and 2 for flow measurement. Flow monitors with relay output (NLSW®45-3 Ex) as well as with relative analog output (NLSW®75-A Ex) are available for this purpose. The scope of delivery includes the evaluation unit and two Zener barriers for installation outside the explosion-protected area.

For environments with SIL1 requirements, we also offer certified devices for flow measurement (NLSW®45-3 SIL1 and sensor F3.x SIL1).

For applications with ATEX and SIL1 requirements, our range includes the NLSW®45-3 Ex SIL1 device, which meets both requirements. Here too, the evaluation unit and the associated Zener barriers are included in the scope of delivery.

Please note that both the evaluation unit and the sensor must be certified accordingly in order to meet the requirements for explosion-protected areas as well as the SIL1 requirements. We will be happy to provide you with all certificates on request at any time.

WHAT SENSOR LENGTH DO I NEED?

A laminar and therefore steady flow without turbulence is required for reliable flow measurement. Experience has shown that this flow occurs in the middle of the air duct or pipe. The sensor should therefore extend into the middle of the duct or pipe.

Air flow sensors are available in standard lengths of 50 mm (Fx), 130 mm (Fx.1), 165 mm (Fx.2), 300 mm (Fx.3), 400 mm (Fx.4) or 500 mm (Fx.5). Special lengths are also easily possible.

Sensors with an immersion depth of 46 or 150 mm are available as standard for measuring the flow of liquid media. We are also happy to provide special solutions here if required.

In addition to the sensor length, the inlet and outlet distances (upstream and downstream of the sensor - usually at least 5 times the pipe or duct diameter) must also be taken into account for optimum measurement results. Installation directly behind a fan or angled pipe or obstacle should be avoided due to turbulence.

WHICH PROCESS CONNECTION DO I NEED?

Various installation options are available for installation in the air duct or pipe. All SEIKOM Electronic sensors for flow measurement have a threaded connection and can therefore be screwed directly into the duct.

Air flow sensors are supplied with a PG7 thread as standard and can be screwed directly into the air duct or pipe.

Using separately available reducers, the sensor can be easily adapted to the process connections M16 x 1.5, M20 x 1.5 or G1/2 inch (or other connections).

Sensors for measuring liquid media (e.g. RLSW®7, F6.x) have a G1/2-inch or G1/4-inch connection as standard.

We also offer screw-in adapters with an M20 x 1.5 external thread. Here you can adjust the immersion depth of the sensor continuously and thus easily identify the optimum measuring point for flow measurement. The sensors can be easily removed for regular cleaning (e.g. in contaminated media, in exhaust gas environments, etc.).

We also offer various mounting flanges as accessories.

ARE THE DEVICES TÜV-CERTIFIED?

Yes, we offer our selected devices for flow measurement with TÜV type examination in accordance with DIN EN 61010-1:2011-07. The devices are certified and regular inspections and quality checks are carried out in our production workshops by our experienced team.