Duct smoke detector - when it comes to smoke detection
Trust on duct smoke detectors from years of specialist professional
In the past 30 years we have developed from Seikom Electronic into one of the leading providers of high-quality measurement and control technology products and have been convincing since then with a TÜV-checked range. With us you will find Printing and modernity Pressure sensory for pressure measurement and air quality sensors for Measure air quality, as well as Room temperature sensor and Temperature switch For precise temperature measurement and much more. At the same time we hold ATEX products ready for you and are one of the few providers when it comes to the areas of Safety Integrity Level and explosion protection. When it comes to security, we may not be missing channel smoke detectors in our selection, so that they are prepared for almost every situation. In addition, our Channel smoke detectors via a valid VDS approval and are available in a DIBT version. This is particularly important when it comes to building inspectorate conditions.
Our plus for you: benefit from our comprehensive services and fast delivery conditions.
What are the qualities of channel smoke detectors?
A sewer smoke detector is essential for the fire detection in ventilation and climate channels of buildings. Using sensors, the device quickly and efficiently detects smoke particles of the air flowing through the canals. As soon as smoke is recognized, the sewer smoke detector triggers an alarm or automatically initiates a process for regulation using the adapter system, such as closing access.
A channel smoke detector also ensures that the manually quick reaction to possible fire or smoke developments, even before they can spread in other areas of the building. The use is particularly important in larger building complexes with extensive ventilation systems in order to ensure the safety of the people in the building and reduce damage to property.
How does a channel smoke detector work?
A channel smoke detector continuously monitors the air that flows through ventilation or climate channels of a building on smoke particles. To do this, it combines a classic smoke detector with an adapter system, whereby the measuring tube and the housing were developed especially for air flow. The optical sensors work with a light beam, mostly a laser that is led through the canal air.
When smoke particles are recognized, the light sprinkles and is captured by the sensor. Ionizing sensors, on the other hand, detect changes in the air ionization caused by smoke. The sewer smoke detector is installed directly in the channel.
As soon as the sewage detector has recognized smoke, it sends a signal to the central fire alarm system, which then raises the alarm. The alarm is used to activate automatic fire protection measures such as triggering sprinkler systems or to initiate manual evacuation measures. Canal smoke detectors are therefore an important part of preventive fire protection in modern buildings.
Where are channel smoke detectors used?
Channel smoke detectors typically are used in buildings with extensive ventilation and air conditioning systems. But they are often indispensable in industrial environments.
Large building and commercial real estate such as office buildings, shopping centers, hotels and other large commercial properties, where there are extensive ventilation systems.
Public institutions, including hospitals, schools, universities, libraries and other public buildings, where it is crucial, to be able to react quickly in the event of a fire.
Production and industrial plantswhere potentially dangerous materials are processed or stored.
In larger residential complexes or high -rise buildingsuse the centralized ventilation systems.
Underground facilities such as subway stations or parking garages in which air exchange is carried out by ventilation systems.
What do you pay attention to when buying a sewer smoke detector?
When buying a channel smoke detector, there are some important points to consider to ensure that the device works effectively and reliably:
Certification and norms
Make sure that the channel smoke detector is certified according to relevant safety and quality standards. In Germany, the devices must correspond to specific standards.
Sensor type
Decide whether an optical or ionizing sensor is suitable for your specific application for a channel smoke detector. Optical sensors are generally better to detect visible smoke, while ionizing sensors can be more effective when detecting flame smoke.
Sensitivity and response behavior
The sensitivity of the smoke detector minimizes false alarms and at the same time ensures that real smoke is recognized early. Some models come with adjustable sensitivity levels or adaptive algorithms that take their special environmental conditions into account.
Integration into existing systems
Make sure that the channel smoke detector is compatible with your existing fire registration system. This includes the ability to integrate into central control systems, alarm devices and any automatic fire protection systems.
Maintenance and test ability
Check how easy to wait and test the channel smoke detector. Models that are easily accessible and have simple test functions make it easier to check and maintain.
How can a channel smoke detector be reliably installed?
Before installing a channel smoke detector, note the assembly conditions in accordance with general conditions and manufacturer information.
Selection selection
Choose a mounting location in the ventilation channel that is representative of the air flow in the system and where the smoke is likely to flow through in a fire. Avoid areas in which turbulence or strong air currents could affect detection using sewer smoke detectors.
accessibility
Install the channel smoke detector at one point that is easily accessible to simplify maintenance work and regular tests.
Consideration of the air speed
The channel smoke detector must be placed in an area of the channel in which the air speed is within the specifications of the detector. Too high or too low air speeds can quickly affect the performance of the sensor.
Use of the right assembly material
Put back on the recommended brackets, brackets and other fastening material from the manufacturer to ensure that the channel smoke detector is firmly and securely installed in the channel.
Electric connections
Make sure that all electrical connections are carried out safely and according to the electrical codes and standards.
Test after installation
After installation, you should test the channel smoke detector. Most channel smoke detectors have a test function that enables the functionality to be checked.
A channel smoke detector contributes significantly to safety and convinces with us with reliability and durability. Feel free to browse through our many more Product categories And please ask us your questions if necessary. We are still there for you personally and competently take on your advice on channel smoke detectors and Co.