Evaluation unit NLSW45-3 Ex SIL1 Analog, flow monitoring for ATEX areas with SIL1 certification and analog output signal optionally 4 ... 20 mA or 0 ... 10 V
Description
Description
✅ Flow monitoring with SIL 1 certification according to IEC 62061 (corresponds to Performance Level c according to EN ISO 13849-1)
✅ Can be used in ATEX Zones 1 and 2 in conjunction with the 2 included Zener barriers
✅ Wide measurement range from 0.1 to 20 m/s with medium temperatures from 0°C to 60°C
✅ With analog output, 4 ... 20 mA, or alternatively 0 ... 10 V, suitable for control cabinet installation
✅ Designed for demanding industrial applications, IP40
✅ Example applications: Flow monitoring in paint shops, paper mills, and research facilities
⚠️ General note regarding the analog outputs:
Iout (-) must not be connected to the negative terminal of the supply voltage, nor to ground or earth.
The power supply to the downstream evaluation unit (e.g., PLC) must be galvanically isolated and must not establish a ground connection.
If necessary, a power isolator must be used.
Evaluation unit NLSW45-3 Ex SIL1 Analog, flow monitoring for ATEX areas with SIL1 certification and analog output signal optionally 4 ... 20 mA or 0 ... 10 V - 24 V DC / 4 ... 20 mA is in stock and is sent as soon as it is available again
Delivery time: Available immediately
Technische Zeichnung 3D: Download
Technische Zeichnung 2D: Download
Bedienungsanleitung DE: Download
Bedienungsanleitung EN: Download
specification
specification
-
MediumGases
-
Device typeFlow evaluation unit for switch cabinet installation
-
Flow range0.1 ... 20 m/s
-
Medium temperature0 ... 60°C
-
DisplayLED (voltage & switching point)
-
Switching pointStepless adjustment (potentiometer)
-
Protection class evaluation unitIP40
-
Special features2 Zener barriers included in the scope of delivery Start-up override 5-60 sec., additional external start-up override
-
Output signalAnalog output, Switching output
-
Switching output specification1 changer
-
Sensor break output signalRelay drops out
-
Sensor short-circuit output signalRelay drops out
-
Relay output specification1 changer
-
Housing materialPolycarbonate glass fiber reinforced (UL94V-0)
-
Housing dimensions120 mm x 45 mm x 73 mm
-
MountingDIN rail; to be mounted outside the ATEX zone
-
Power supply24 V DC ±5%, 24 V AC ±5%, 230 V AC ±5%
-
Electrical connectionTerminal strip
-
Max. power consumption3 VA
-
Recommended cable cross-section2.5 mm²
-
Current and contact rating250 VAC, 8 A, 2 kVA
-
Minimum switching capacity10 mA, 5 V DC
-
Ambient temperature-20 ... 50°C
-
CertificatesCE
-
ATEX certificationII 3G Ex ic IIC T4 Gc, simple electrical equipment; Zone 1
-
SIL levelSIL1
-
Country of origin
-
Customs tariff number
-
HS code
Frequently Asked Questions
Welche Vorteile bietet der NLSW45-3 Ex SIL1 Analog gegenüber Standard-Luftstromwächtern?
Welche Vorteile bietet der NLSW45-3 Ex SIL1 Analog gegenüber Standard-Luftstromwächtern?
Wo wird der NLSW45-3 Ex SIL1 Analog eingesetzt?
Wo wird der NLSW45-3 Ex SIL1 Analog eingesetzt?
Wie erfolgt der Einbau der Zener-Barrieren und worauf ist zu achten?
Wie erfolgt der Einbau der Zener-Barrieren und worauf ist zu achten?
Wie funktioniert der Analogausgang?
Wie funktioniert der Analogausgang?
Welche Sensorvarianten/Fühlerlängen sind möglich?
Welche Sensorvarianten/Fühlerlängen sind möglich?
Wie wird das Gerät gewartet?
Wie wird das Gerät gewartet?