Electromagnetic flowmeter FlowGuard® FT410
Description
Description
✅ High-precision electromagnetic flow measurement for DN4 to DN600
✅ Measurement accuracy ≤0.5% of the measured value, repeatability 0.2%
✅ Bidirectional measurement of flow velocities ranging from 0.06 to 12 m/s, depending on the model
✅ Compact or remote design for maximum installation flexibility
✅ Temperature-resistant up to 150°C (remote) or 90°C (compact), depending on the lining
✅ Wide range of linings: PTFE, PFA, ETFE, PVDF, rubber, RILSAN
✅ Rugged IP65/IP67/IP68 protection ratings for demanding environments
✅ Corrosion-resistant electrodes made of stainless steel, Hastelloy, titanium, or tantalum
✅ Extensive range of process connections: flange, threaded, sandwich, clamp
✅ Multiple output signals: 4 ... 20 mA, pulses, HART, Modbus, RS485
✅ Empty conduit detection and advanced diagnostic functions available
✅ Battery operation available upon request, for off-grid field applications
✅ MID-compliant version (e.g., for metered billing) available upon request
✅ Suitable for conductive media with a conductivity of 5 µS/cm or higher
✅ Maintenance-free due to no moving parts in the measuring tube
✅ DNV version available upon request
Electromagnetic flowmeter FlowGuard® FT410 - DN4 / Thread / PVDF is in stock and is sent as soon as it is available again
Delivery time: Selected variants available immediately
Technische Zeichnung 3D: Download
Technische Zeichnung 2D: Download
Bedienungsanleitung DE: Download
Datenblatt DE: Download
Datenblatt EN: Download
specification
specification
-
MediumLiquids
-
Device typeMagnetic inductive flow meter
-
Device designCompact device, with remote evaluation unit (standard cable length 3 m)
-
Flow rangeBidirectional measurement, depending on the model:, 0.2 ... 12 m/s, (1/60) , 0.12 ... 12 m/s, (1/100) , 0.06 … 12 m/s, (1/200)
-
Flow accuracy≤0.5% of the measured value
-
Medium temperatureCompact: max. 90°C (depending on model), Off: max. 170°C (depending on model)
-
DisplayLCD display, 2×16 characters
-
Protection class evaluation unitStandard device (H - head) - IP65, Front device (F) - IP67, Panel device (P) - IP54
-
Protection class sensorIP65, IP67, IP68
-
Special featuresEmpty pipe detection DN15 ... DN600, Pressure loss negligible, Additional electrodes for earthing and detection of empty pipes
-
Output signalPulse output, Analog output, Digital output
-
Sensor break output signal<3.5 mA
-
Process connectionFlanged DIN (EN1092) - Carbon or stainless steel, Sandwich (PN25 only), Thread (EN 10226-1) food grade (DIN 11851 fitting, clamp)
-
Housing materialSteel ST37 (coated), Stainless steel flange SS304, Stainless steel flange SS316
-
Sensor materialStainless steel DIN 1.4571, Hastelloy C4, Titanium, Tantalum
-
Pressure resistancePN10, PN16, PN25, PN40, PN64, PN100, JIS: 10K, JIS: 20K, JIS: 40K, ANSI: 150lb, ANSI: 300lb
-
DiameterDN4 ... 600 (other diameters on request)
-
Power supply24 V AC/ DC with reverse polarity protection, 230 V AC (50/60 Hz), 110 V AC (60Hz), Internal battery 12 V DC (not all variants available)
-
Electrical connectionTerminal 1 & 2: Analog output 4...20 mA, Terminal 3 & 4: Pulse output / flow switch 1, Terminal 5 & 6: RS485, Terminal 7 & 8: Pulse output / flow switch 2, Terminal 9 & 10: Reset of the volume register, Terminal 11 & 12: Output voltage 16V/100mA (power supply for switching to active current and pulse outputs), Terminal L, N, PE: Power supply
-
Max. power consumption4.6 VA
-
Ambient temperature0 ... 55°C
-
CertificatesCE
-
ATEX certificationnone
-
SIL levelnone
-
Country of origin
-
Customs tariff number
-
HS code
-
Signal output reproducibility0,2%