Electromagnetic flowmeter FlowGuard® FT480 with heat and cold flow meter
Description
Description
✅ High-precision electromagnetic flow measurement for DN4 to DN600
✅ Measurement accuracy ≤0.5% of the measured value, repeatability 0.2%
✅ Bidirectional measurement of flow velocities ranging from 0.06 to 12 m/s, depending on the model
✅ Compact or remote design for maximum installation flexibility
✅ Temperature-resistant up to 150°C (remote) or 90°C (compact), depending on the lining
✅ Wide range of linings: PTFE, PFA, ETFE, PVDF, rubber, RILSAN
✅ Rugged IP65/IP67/IP68 protection ratings for demanding environments
✅ Corrosion-resistant electrodes made of stainless steel, Hastelloy, titanium, or tantalum
✅ Extensive range of process connections: flange, threaded, sandwich, clamp
✅ Multiple output signals: 4 ... 20 mA, pulses, HART, Modbus, RS485
✅ Empty tube detection and advanced diagnostic functions available
✅ Battery operation available upon request, for off-grid field applications
✅ MID-compliant version (e.g., for metered billing) available upon request
✅ Suitable for conductive media with a conductivity of 5 µS/cm or higher
✅ Maintenance-free due to no moving parts in the measuring tube
Electromagnetic flowmeter FlowGuard® FT480 with heat and cold flow meter - DN10 / Thread / PFA is in stock and is sent as soon as it is available again
Delivery time: Available in 3-4 weeks
specification
specification
-
MediumLiquids
-
Device typeMagnetic inductive flow meter
-
Device designCompact device, with remote evaluation unit (standard cable length 3 m)
-
Flow rangeBidirectional measurement, depending on the model:, 0.2 ... 2 m/s, (1/60) , 0.12 ... 2 m/s, (1/100) , 0.06 … 12 m/s, (1/200) , For calibrated devices used for billing purposes:, Selectable from (1/25), (1/50), or (1/100)
-
Flow accuracy≤0.5% of the measured value
-
Medium temperatureCompact: max. 90°C (depending on version), Remote: max. 150°C (depending on version)
-
DisplayLCD display, 2×16 characters
-
Protection class evaluation unitStandard device (H - head) - IP65, Front device (F) - IP67, Panel device (P) - IP54
-
Protection class sensorIP65, IP67, IP68
-
Protection class housingIP65, IP67, IP68
-
Special featuresEmpty pipe detection DN15 ... DN600, Pressure loss negligible, Additional electrodes for earthing and detection of empty pipes
-
Temperature resolution0,5°C
-
Output signalPulse output, Analog output, Digital output
-
Sensor break output signal<3.5 mA
-
Process connectionSandwich (PN25 only), Flanged DIN (EN1092) - Carbon or stainless steel, Thread (EN 10226-1) Food grade (DIN 11851 fitting, clamp)
-
Housing materialStainless steel, Steel ST37 (coated)
-
Sensor materialStainless steel DIN 1.4571, Hastelloy C4, Titanium, Tantalum
-
Pressure resistancePN10, PN16, PN25, PN40
-
DiameterDN10 ... 600 (other diameters on request)
-
Power supply24 VAC/ VDC with reverse polarity protection, 230 VAC (50/60 Hz), 110 VAC (60Hz), Battery
-
Max. power consumption9.6 VA
-
Ambient temperature0 ... 55°C
-
CertificatesCE
-
ATEX certificationnone
-
SIL levelnone
-
Country of origin
-
Customs tariff number
-
HS code
-
Signal output reproducibility0,2%
Frequently Asked Questions
Welche Rohrdurchmesser und Prozessanschlüsse sind beim FlowGuard FT480 verfügbar?
Welche Rohrdurchmesser und Prozessanschlüsse sind beim FlowGuard FT480 verfügbar?
Kann der FlowGuard FT480 in verschiedenen Einbaulagen montiert werden?
Kann der FlowGuard FT480 in verschiedenen Einbaulagen montiert werden?
Welche Wartungsintervalle sind beim FlowGuard FT480 einzuhalten?
Welche Wartungsintervalle sind beim FlowGuard FT480 einzuhalten?
Für welche Anwendungen ist der FlowGuard FT480 optimal geeignet?
Für welche Anwendungen ist der FlowGuard FT480 optimal geeignet?
Was unterscheidet den FlowGuard FT480 von Standard-Durchflussmessern?
Was unterscheidet den FlowGuard FT480 von Standard-Durchflussmessern?
Wie erfolgt die Systemintegration des FlowGuard FT480 in bestehende Leitsysteme?
Wie erfolgt die Systemintegration des FlowGuard FT480 in bestehende Leitsysteme?
Welche Kommunikationsprotokolle unterstützt der FlowGuard FT480 und wie unterscheiden sich M-Bus und Modbus RTU?
Welche Kommunikationsprotokolle unterstützt der FlowGuard FT480 und wie unterscheiden sich M-Bus und Modbus RTU?
Was bedeutet die MID-Zertifizierung beim FlowGuard FT480 und warum ist sie für Wärmemengenmessung wichtig?
Was bedeutet die MID-Zertifizierung beim FlowGuard FT480 und warum ist sie für Wärmemengenmessung wichtig?