Evaluation unit NLSW45-3 Ex SIL2 Analog, flow monitoring for ATEX areas with SIL2 certification
Description
Description
✅ Flow monitoring with SIL 2 certification according to IEC 62061 (corresponds to Performance Level d according to EN ISO 13849-1)
✅ Can be used in ATEX Zones 1 and 2 in conjunction with the 4 included Zener barriers
✅ Wide measurement range from 0.1 to 20 m/s with medium temperatures from 0°C to 60°C
✅ Suitable for control cabinet installation with analog and switching outputs
✅ Designed for demanding industrial applications, IP40
✅ Redundant design of the evaluation electronics and use of 2 sensors required
✅ Example applications: HVAC systems, fire and smoke protection systems, industrial and process applications, power plants and energy facilities, the automotive industry, and test benches
⚠️ General note regarding the analog outputs:
Iout (-) must not be connected to the negative terminal of the supply voltage, nor to ground or earth.
The power supply to the downstream evaluation unit (e.g., PLC) must be electrically isolated and must not establish a ground connection.
If necessary, an isolation transformer must be used.
Evaluation unit NLSW45-3 Ex SIL2 Analog, flow monitoring for ATEX areas with SIL2 certification - 24 V DC is in stock and is sent as soon as it is available again
Delivery time: Available immediately
Technische Zeichnung 3D: Download
Technische Zeichnung 2D: Download
Bedienungsanleitung DE: Download
Bedienungsanleitung EN: Download
specification
specification
-
MediumGases
-
Device typeFlow evaluation unit for switch cabinet installation
-
Flow range0.1 ... 20 m/s
-
Medium temperature0 ... 60°C
-
DisplayLED (voltage & switching point)
-
Switching pointStepless adjustment (potentiometer)
-
Protection class evaluation unitIP65
-
Special features4 Zener barriers included in the scope of delivery, 2 sensors required (SIL2)
-
Output signalSwitching output, Analog output
-
Switching output specification2 changeover contacts (per channel)
-
Sensor break output signalRelay drops out
-
Sensor short-circuit output signalRelay drops out
-
Relay output specification2 changeover contacts (per channel)
-
Housing materialPolyamide (UL94V-0)
-
Housing dimensions85 mm x 165 mm x 55 mm
-
MountingMounting kit included, Mounting on DIN rail optional, to be mounted outside the ATEX zone
-
Power supply24 V DC ±5%, 230 V AC ±5%
-
Electrical connectionTerminal strip
-
Max. power consumption5 VA
-
Recommended cable cross-section2.5 mm²
-
Current and contact rating250 V AC, 8 A, 2 kVA
-
Minimum switching capacity10 mA, 5 V DC
-
Ambient temperature-20 ... 50°C
-
CertificatesCE
-
ATEX certificationII 3G Ex ic IIC T4 Gc, simple electrical equipment; Zone 1
-
SIL levelSIL2
-
Country of origin
-
Customs tariff number
-
HS code
Frequently Asked Questions
Was unterscheidet den NLSW45-3 Ex SIL2 Analog von Standard-Luftstromwächtern und warum SIL2?
Was unterscheidet den NLSW45-3 Ex SIL2 Analog von Standard-Luftstromwächtern und warum SIL2?
Welche Zener-Barrieren sind enthalten und warum dürfen SZB7601/SZB7602 nicht vertauscht werden?
Welche Zener-Barrieren sind enthalten und warum dürfen SZB7601/SZB7602 nicht vertauscht werden?
Welche F3.x Ex SIL2 Sensoren sind erforderlich und warum paarige Kalibrierung?
Welche F3.x Ex SIL2 Sensoren sind erforderlich und warum paarige Kalibrierung?
Wie funktionieren die Dual-Analogausgänge und welche Anwendungen sind möglich?
Wie funktionieren die Dual-Analogausgänge und welche Anwendungen sind möglich?
Welche ATEX-Installationsvorschriften gelten für Zone 1,2 und wer darf installieren?
Welche ATEX-Installationsvorschriften gelten für Zone 1,2 und wer darf installieren?
Welche Wartungsintervalle gelten für Ex-Bereiche nach IEC 60079-17?
Welche Wartungsintervalle gelten für Ex-Bereiche nach IEC 60079-17?
Für welche sicherheitskritischen Anwendungen ist der NLSW45-3 Ex SIL2 Analog entwickelt?
Für welche sicherheitskritischen Anwendungen ist der NLSW45-3 Ex SIL2 Analog entwickelt?
Welche Installationsfehler können beim NLSW45-3 Ex SIL2 Analog auftreten?
Welche Installationsfehler können beim NLSW45-3 Ex SIL2 Analog auftreten?