Evaluation unit NLSW45-3 SIL2 Analog, flow monitoring with SIL2 certification and analog output (4-20 mA)
Description
Description
✅ Redundant SIL2 airflow monitor in accordance with IEC 62061 (Performance Level d)
✅ Dual safety: 2 calibrated F3.x SIL2 sensors + redundant evaluation electronics
✅ Per channel: 1 changeover relay + 4 ... 20 mA / 0 ... 10 V analog signal
✅ Measurement range 0.1 ... 30 m/s, medium temperature 0 ... 85°C, high process reliability
✅ 6 sensor configurations: 50 ... 500 mm length, factory-calibrated for each channel
✅ Compact IP65 housing (165×85×55 mm), optional DIN rail mounting
✅ Continuously adjustable switching points and analog ranges, independently of one another
✅ Start-up delay 5 … 60 s, LED indicators for each channel
✅ Cable extension up to 50 m possible; shielding recommended for EMC exposure
✅ Safety-critical applications: chemical, pharmaceutical, power plants, hydrogen
✅ Optional: ATEX version with 4 Zener barriers available for Zones 1 and 2
✅ Easy to maintain: Compliant with IEC 60079-17, simple sensor cleaning
✅ CE/UKCA certified, Exida SIL 2 classified (IEC 61508 SIL 2: March 2023)
⚠️ General note regarding the analog outputs:
Iout (-) must not be connected to the negative terminal of the supply voltage, nor to ground or earth.
The power supply to the downstream evaluation unit (e.g., PLC) must be galvanically isolated and must not establish a ground connection.
If necessary, a power isolator must be used.
Evaluation unit NLSW45-3 SIL2 Analog, flow monitoring with SIL2 certification and analog output (4-20 mA) - 230 V AC is in stock and is sent as soon as it is available again
Delivery time: Available immediately
Technische Zeichnung 3D: Download
Technische Zeichnung 2D: Download
Bedienungsanleitung DE: Download
Bedienungsanleitung EN: Download
specification
specification
-
MediumGases
-
Device typeFlow evaluation unit for switch cabinet installation, Installation at the measuring point
-
Flow range0,1 ... 30 m/s
-
Medium temperature0 ... 85°C
-
DisplayLED (voltage & switching point)
-
Switching pointStepless adjustment (potentiometer), Independent of the analog measuring range
-
Protection class evaluation unitIP65
-
Special features2 sensors required (SIL2)
-
Output signalSwitching output, Analog output
-
Switching output specification2 changeover contacts (per channel)
-
Sensor break output signalRelay drops out
-
Sensor short-circuit output signalRelay drops out
-
Relay output specification2 changeover contacts (per channel)
-
Housing materialPolyamide (UL94V-0)
-
Weight
-
Housing dimensions85 mm x 165 mm x 55 mm
-
MountingMounting kit included, Mounting on DIN rail optional
-
Power supply24 V AC/DC ±10%, 230 V AC ±10%
-
Electrical connectionTerminal strip
-
Max. power consumption5 VA
-
Recommended cable cross-section2.5 mm²
-
Current and contact rating250 V AC, 4 A, 1 kVA / 150W
-
Minimum switching capacity100 mA/ 5 V DC
-
Ambient temperature-20 ... 60°C
-
CertificatesCE
-
ATEX certificationnone
-
SIL levelSIL2
-
Country of origin
-
Customs tariff number
-
HS code
Frequently Asked Questions
Was bedeutet "redundant" beim NLSW45-3 SIL2 Analog?
Was bedeutet "redundant" beim NLSW45-3 SIL2 Analog?
Können beide Analogausgänge (4–20mA und 0–10V) gleichzeitig genutzt werden?
Können beide Analogausgänge (4–20mA und 0–10V) gleichzeitig genutzt werden?
Welche Sensorbauformen stehen zur Verfügung?
Welche Sensorbauformen stehen zur Verfügung?
Wie werden die beiden Sensoren im Rohr positioniert?
Wie werden die beiden Sensoren im Rohr positioniert?
Ist eine ATEX-Version verfügbar?
Ist eine ATEX-Version verfügbar?
Welche Wartungsintervalle gelten für SIL2-Anwendungen?
Welche Wartungsintervalle gelten für SIL2-Anwendungen?
Was passiert bei Sensorfehler oder -ausfall?
Was passiert bei Sensorfehler oder -ausfall?