RLSW8 volumetric flow meter for measuring the flow of gases up to 350°C
Description
Description
✅ RLSW8 LCD Microcontroller Airflow Sensor with a 10-LED chain, LCD display, and intelligent menu system for 0.1 ... 30 m/s (optional 200 m/s)
✅ Extreme temperatures up to 350°C: Standard -25 ... 80°C, optional -25 ... 250/350°C for high-temperature industrial applications and exhaust gas measurements
✅ Intelligent self-monitoring: continuous monitoring of the sensor, electronics, and cables with error code display and fail-safe function
✅ Dual-output system: SPNO relay 200 V/1 A + NPN open collector 250 mA + linear analog outputs 0 ... 10 V/4 ... 20 mA for PLC integration
✅ M8 sensor option: remote sensor with 2.5 m industrial cable, calibrated in pairs for flexible installation up to 250/350°C medium temperature
✅ 10-point menu system: Language, flow min/max, pipe diameter, alarm settings via T1/T2 buttons with “Save and Exit” function
✅ Advanced display features: 10-LED chain for percentage display, flashing setpoint LED, LCD switch between absolute and relative values
✅ Volume flow calculation: max. 63,000 m³/h and l/min with freely selectable units (m/s ↔ m³/h ↔ l/min) via menu settings
✅ Factory presets: Ready for immediate operation after installation/wiring; customization via the LCD menu possible at any time
✅ Rugged construction: IP54 housing/IP67 sensor, 10 bar pressure resistance, nickel-plated MS (stainless steel optional), PG7 process connection
✅ Professional installation: 9-terminal connection 1.5 mm², VDE-compliant wiring, 24 V DC ±5% power supply, CE-certified
✅ Premium applications: Extrusion lines, exhaust gas measurements, test benches, filter monitoring, PLC-controlled process regulation up to 350°C
RLSW8 volumetric flow meter for measuring the flow of gases up to 350°C - Compact device / -25 ... 80°C / 50 mm is in stock and is sent as soon as it is available again
Delivery time: Available in 2-3 days
Technische Zeichnung 3D: Download
Technische Zeichnung 2D: Download
Bedienungsanleitung DE: Download
Bedienungsanleitung EN: Download
specification
specification
-
MediumGases
-
Device typeCompact flow device
-
Device designCompact device including sensor (permanently mounted), Compact device including sensor (remote)
-
Flow range0,1 ... 30 m/s (optionally available up to 200 m/s)
-
Flow accuracy±5% of the measuring range end value, Reproducibility ±2% of full scale value
-
Medium temperature-25 ... 80°C, -25 ... 250°C, -25 ... 350°C
-
DisplayLCD, Yellow LED for flow velocities > switching point, green LED during operation, 10 red LEDs for the flow velocity in 10% steps
-
Protection class evaluation unitIP65
-
Protection class sensorP67
-
Special featuresLinear analog output Flow velocities up to 200 m/s measurable Adjustable start-up delay 0 ... 60 s Velocity dimensions: m/s, l/min, m³/h, Linear analog output Applicable up to 350°C Medium temperature Flow velocities up to 200 m/s measurable Adjustable start-up bridging 0 ... 60 s Velocity dimensions: m/s, l/min, m³/h
-
Output signalSwitching output, Analog output
-
Switching output specification1 NO contact (closes/opens with flow, adjustable)
-
Sensor break output signalFault-specific error codes in the LCD, 4 mA, Relay drops out
-
Sensor short-circuit output signalFault-specific error codes in the LCD, 4 mA, Relay drops out
-
Relay output specification1 NO contact (closes/opens with flow, adjustable)
-
Immersion depth50, 130, 165, 300, 400, 500
-
Process connectionPG7, Optional G1/2-inch connection using a reducer
-
Housing materialPolyamide, UL94-V0
-
Sensor materialMS58, nickel-plated (optionally available in stainless steel), Stainless steel 1.4571
-
Pressure resistance10 bar
-
Housing dimensions56 mm x 84 mm x 80 mm
-
Power supply24 V DC ±5%
-
Electrical connection9 terminals (max. 1.5 mm²)
-
Max. power consumption4 VA
-
Current and contact rating200 V AC/DC, 1 A
-
Minimum switching capacity10 mA, 5 V DC
-
Ambient temperature-20 ... 60°C
-
Optimal inlet path>10 DN
-
Optimal outlet path>5 DN
-
Temperature gradient
-
CertificatesCE
-
ATEX certificationnone
-
SIL levelnone
-
Country of origin
-
Customs tariff number
-
HS code
-
Pollution degree
Frequently Asked Questions
Was unterscheidet den RLSW8 LCD vom RLSW5A und welche Microcontroller-Vorteile bietet er?
Was unterscheidet den RLSW8 LCD vom RLSW5A und welche Microcontroller-Vorteile bietet er?
Welche Extreme-Temperatur-Optionen bietet der RLSW8 und für welche Anwendungen?
Welche Extreme-Temperatur-Optionen bietet der RLSW8 und für welche Anwendungen?
Wie funktioniert das M8-Sensor-System beim RLSW8 und welche Installation-Vorteile bietet es?
Wie funktioniert das M8-Sensor-System beim RLSW8 und welche Installation-Vorteile bietet es?
Welche intelligenten Display-Features bietet der RLSW8 LCD?
Welche intelligenten Display-Features bietet der RLSW8 LCD?
Wie erfolgt die Menü-Programmierung beim RLSW8 und welche Parameter sind einstellbar?
Wie erfolgt die Menü-Programmierung beim RLSW8 und welche Parameter sind einstellbar?
Welche Ausgangs-Konfigurationen bietet der RLSW8 für SPS-Integration?Welche Selbstüberwachung-Funktionen bietet der RLSW8 für Betriebssicherheit?
Welche Ausgangs-Konfigurationen bietet der RLSW8 für SPS-Integration?Welche Selbstüberwachung-Funktionen bietet der RLSW8 für Betriebssicherheit?
Welche Selbstüberwachung-Funktionen bietet der RLSW8 für Betriebssicherheit?
Welche Selbstüberwachung-Funktionen bietet der RLSW8 für Betriebssicherheit?
Für welche Premium-Anwendungen ist der RLSW8 besonders geeignet?
Für welche Premium-Anwendungen ist der RLSW8 besonders geeignet?