F3 Ex SIL1 Sensor
Description
Description
✅ Sensors for flow monitoring of gases in potentially explosive atmospheres (ATEX) Zones 1 and 2
✅ Classified according to Safety Integrity Level 1 (SIL1), also available with SIL2 classification
✅ Measurement range 0.1 to 20.0 m/s
✅ Standard cable length 2.5 m—optionally extendable up to 30 m
✅ For easy installation and alignment of the sensor in the airflow: Use a screw-in adapter with ATEX certification (sold separately)
✅ Material: Nickel-plated brass (standard), alternatively available in stainless steel (V4A) or Teflon
✅ Custom lengths available upon request
✅ Depending on the desired output signal, use with:
- NLSW®45-3 Ex SIL1 evaluation unit (for monitoring an adjustable switching point)
- NLSW®45-3 Ex SIL1 Analog Evaluation Unit (for analog signals (4–20 mA or 0–10 V), as well as for monitoring an adjustable switching point)
⚠️ Probe >300 mm in VA (F3 SIL1 VA)
F3 Ex SIL1 Sensor - 50 / 2,5 / MS58 nickel-plated is in stock and is sent as soon as it is available again
Delivery time: Available immediately
Technische Zeichnung 3D: Download
Technische Zeichnung 2D: Download
Bedienungsanleitung DE: Download
Bedienungsanleitung EN: Download
specification
specification
-
MediumGases
-
Device typeFlow sensor
-
Device designSensor
-
Flow range0.1 m/s ... 20 m/s
-
Medium temperature0°C ... 60°C
-
Protection class sensorIP67
-
Immersion depth50 mm, 130 mm, 165 mm, 300 mm, 400 mm, 500 mm, Special lengths on request
-
Process connectionPG7, Optional G1/2-inch connection using a reducer
-
Sensor materialMS58 nickel-plated, other materials on request (e.g. 1.4571)
-
Pressure resistance10 bar
-
Electrical connectionStandard cable length: 2.5 m, Custom lengths available upon request
-
Temperature gradient
-
CertificatesCE, Type-tested by TÜV Nord in accordance with DIN EN 61010-1 2011-07
-
ATEX certificationII 3G Ex ic IIC T4 Gc, simple electrical equipment; Zone 1
-
SIL levelSIL1
-
Customs tariff number
-
HS code
Frequently Asked Questions
Was ist die Besonderheit der dualen Zertifizierung (Ex + SIL1)?
Was ist die Besonderheit der dualen Zertifizierung (Ex + SIL1)?
Darf der F3 Ex SIL1 in Zone 1 eingesetzt werden?
Darf der F3 Ex SIL1 in Zone 1 eingesetzt werden?
Was ist der Unterschied zu F3 Ex ohne SIL1?
Was ist der Unterschied zu F3 Ex ohne SIL1?
Was bedeutet "Performance Level c"?
Was bedeutet "Performance Level c"?
Welche Zener-Barrieren sind erforderlich?
Welche Zener-Barrieren sind erforderlich?
Kann das Anschlusskabel verlängert werden?
Kann das Anschlusskabel verlängert werden?
Ist eine jährliche TÜV-Prüfung erforderlich?
Ist eine jährliche TÜV-Prüfung erforderlich?
Welche besonderen Vorsichtsmaßnahmen gibt es bei Wasserstoff?
Welche besonderen Vorsichtsmaßnahmen gibt es bei Wasserstoff?