Compact flow monitor RLSW5 F3 with relay output

Sku: 80447F3/50

Description

✅ RLSW5 F3 Temperature and Airflow Monitor for media temperatures ranging from -20 to 90°C and a temperature gradient tolerance of 30 K/min

✅ TÜV NORD-certified according to DIN EN 61010-1:2011-07 with a calorimetric dual-resistor system for maintenance-free flow measurement from 0.1 to 30 m/s

✅ SPDT changeover relay output 250 V AC/6 A/1.5 kVA with NO+NC contacts for complex interlocks and redundancy circuits

✅ Dual power supply: 24 V AC/DC or 230 V AC for flexible integration in industrial systems without external power supplies

✅ Rugged IP67 sensor system with MS58 nickel-plated housing (optional V4A stainless steel or Teflon) for extreme environmental conditions up to 10 bar

✅ Six immersion depths available: 50, 130, 165, 300, 400, 500 mm for optimal adaptation to various duct sizes

✅ 60-second start-up delay, activatable via jumper, prevents false alarms in industrial fans that start slowly

✅ Versatile process connections: PG7 standard, G1/2", G1/4" via reducer, separate mounting flange for duct installation

✅ Precise potentiometer setpoint adjustment with LED status indicators (Green = Operation, Yellow = Flow > Threshold)

✅ Special applications: cold rooms, drying ovens, combustion chambers, climate chambers, outdoor installations, rapid temperature change processes

✅ Larger electronics unit (56×84×80 mm) compared to the RLSW4R for expanded functionality and higher switching capacity

Immersion depth
Power supply
Lieferzeit Symbol Delivery time: Available immediately

TÜV Baumusterprüfung: Download

Technische Zeichnung 3D: Download

Technische Zeichnung 2D: Download

Bedienungsanleitung DE: Download

Bedienungsanleitung EN: Download

Delivery and shipping

Immediately available from stock

Compact flow monitor RLSW5 F3 with relay output

Away €223,10

✅ RLSW5 F3 Temperature and Airflow Monitor for media temperatures ranging from -20 to 90°C and a temperature gradient tolerance of 30 K/min

✅ TÜV NORD-certified according to DIN EN 61010-1:2011-07 with a calorimetric dual-resistor system for maintenance-free flow measurement from 0.1 to 30 m/s

✅ SPDT changeover relay output 250 V AC/6 A/1.5 kVA with NO+NC contacts for complex interlocks and redundancy circuits

✅ Dual power supply: 24 V AC/DC or 230 V AC for flexible integration in industrial systems without external power supplies

✅ Rugged IP67 sensor system with MS58 nickel-plated housing (optional V4A stainless steel or Teflon) for extreme environmental conditions up to 10 bar

✅ Six immersion depths available: 50, 130, 165, 300, 400, 500 mm for optimal adaptation to various duct sizes

✅ 60-second start-up delay, activatable via jumper, prevents false alarms in industrial fans that start slowly

✅ Versatile process connections: PG7 standard, G1/2", G1/4" via reducer, separate mounting flange for duct installation

✅ Precise potentiometer setpoint adjustment with LED status indicators (Green = Operation, Yellow = Flow > Threshold)

✅ Special applications: cold rooms, drying ovens, combustion chambers, climate chambers, outdoor installations, rapid temperature change processes

✅ Larger electronics unit (56×84×80 mm) compared to the RLSW4R for expanded functionality and higher switching capacity

Medium

Gases

Device type

Compact flow device

Device design

Compact device including sensor (permanently mounted)

Temperature range

Temperature accuracy

Flow range

0,1 ... 30 m/s

Flow accuracy

Medium temperature

-20 ... 90°C

Relative pressure range

Relative pressure accuracy

Atmospheric pressure range

Atmospheric pressure accuracy

Measured variable

Differential pressure range

Differential pressure accuracy

VOC range

VOC accuracy

CO₂ range

CO₂ accuracy

Relative humidity range

Relative humidity accuracy

Number of differential pressure ranges

Maximum measuring range limit

Display

Yellow LED at flow velocities > switching point, green LED during operation

Switching point

Stepless adjustment (potentiometer)

Protection class evaluation unit

IP65

Protection class sensor

IP67

Protection class housing

IP65

Special features

Activatable start-up delay 0 ... 60 s

Cable length

IK impact resistance rating

Luminous flux

Emergency luminous flux

Efficiency

Light color

Color rendering index CRI

Flicker factor

Power factor

Humidity resolution

Temperature resolution

Max. differential pressure

Adjustment range

product.metafields.custom.messgroesse1

Output signal

Switching output

Analog output specification

Switching output specification

Relay picks up on flow (changeover contact)

Digital output specification

Sensor break output signal

Relay drops out

Sensor short-circuit output signal

Relay drops out

Analog input

Digital input

Relay output specification

Relay picks up on flow (changeover contact)

Immersion depth

50 mm, 130 mm, 165 mm, 300 mm, 400 mm, 500 mm, Special lengths on request

Process connection

PG7, Optional G1/2-inch connection using a reducer

Housing material

Polyamide, UL94-V0

Connection head material

Sensor material

MS58, nickel-plated (optionally available in stainless steel)

Pressure resistance

10 bar

Overpressure limit

Weight

Operating pressure

Housing dimensions

56 mm x 84 mm x 80 mm

Mounting

Minimum pipe diameter

Fastening strap specification

Burst pressure

Vacuum resistance

Dimensions

Cable gland

Diameter

Installation depth

Front cover material

Sensor response length

Capillary tube length

Max. pressure

Power supply

24 V AC/DC ±5%, 230 V AC ±5%

Electrical connection

5 terminals (2.5 mm²)

Max. power consumption

3 VA

Power

Recommended cable cross-section

Load resistance

Insulation resistance

Current and contact rating

250 VAC, 6 A, 1.5 kVA

Response time

Minimum switching capacity

10 mA, 5 V DC

Protection class

Min. output power

Self-consumption

product.metafields.custom.leistung Bürde max.

Max. input current

Measuring resistor

Switching differential

Overvoltage category

Reverse polarity protection

Supply output

Sensor element type

Ambient temperature

-20 ... 60°C

Storage temperature

Ambient humidity

Ambient pressure

Temperature compensation

Optimal inlet path

>5 DN

Optimal outlet path

>3 DN

Temperature gradient

30K/min

Certificates

CE, Type-tested by TÜV Nord in accordance with DIN EN 61010-1 2011-07

ATEX certification

none

SIL level

none

Country of origin

Germany

Customs tariff number

90 26 80 20

HS code

90 26 80

Warranty

Service life

Fire protection

Alarm

Lining

Color

Output signal accuracy LCD/Modbus

Manufacturer

Notes

Hysteresis

Conformity

Long-term stability

Material contact

Media compatibility

Emergency light

Certification mark

Signal output reproducibility

Switching function (flow)

Fuse

Wet bulb temperature spec.

Dew point temperature spec.

Absolute humidity spec.

Availability

Pollution degree

II

Heat dissipation

Repeatability

Permissible air velocity

Internal thread

External thread

Wrench size

Inner diameter

Accessories

Show product