Electromagnetic flowmeter FlowGuard® FT410

Sku: 1315/K/DN4/G/PN16/PVDF/ST/65/1/24

Description

✅ Flow measurement from 0.06 to 12 m/s

✅ Bidirectional measurement with direction detection and empty pipe detection

✅ With pulse output, analog signal (4-20 mA), HART and Modbus connection

✅ Various process connections and linings ideal for your process, with drinking water approval on request

✅ Special versions are also suitable as heat meters or for use in ATEX environments

✅ Optionally available up to protection class IP68 and therefore ideal for industrial use

✅ Manufactured for you and available at short notice within ~3 weeks

Diameter
Process connection
Lining
€1.430,00
Shipment is calculated in the checkout.
Lieferzeit Symbol Delivery time: Selected variants available immediately

Technische Zeichnung 2D: Download

Bedienungsanleitung DE: Download

Datenblatt DE: Download

Datenblatt EN: Download

specification

  • Medium
    Liquids
  • Geräte-Typ
    Magnetic inductive flow meter
  • Geräte-Bauart
    Compact device, with remote evaluation unit (standard cable length 3 m)
  • Messbereich Strömung
    0.06 ... 12m/s, bidirectional measurement, max. (1/200)
  • Messgenauigkeit Strömung
    ≤0.5% of the measured value
  • Medientemperatur
    Compact: max. 90°C (depending on version), Remote: max. 150°C (depending on version)
  • Anzeige
    LCD display, 2×16 characters
  • Schutzart Auswerteeinheit
    Standard device (H - head) - IP65, Front device (F) - IP67, Panel device (P) - IP54
  • Schutzart Sensor
    IP65, IP67, IP68
  • Besonderheiten
    Empty pipe detection DN15 ... DN600, Pressure loss negligible, Additional electrodes for earthing and detection of empty pipes
  • Ausgangssignal
    Pulse output, Analog output, Digital output
  • Signalausgang Sensorbruch
    <3.5 mA
  • Prozessanschluss
    Sandwich (PN25 only), Flanged DIN (EN1092) - Carbon or stainless steel, Thread (EN 10226-1) Food grade (DIN 11851 fitting, clamp)
  • Material Gehäuse
    Stainless steel, Steel ST37 (coated)
  • Material Sensor
    Stainless steel DIN 1.4571, Hastelloy C4, Titanium, Tantalum
  • Druckfestigkeit
    PN10, PN16, PN25, PN40, PN64, PN100, JIS: 10K, JIS: 20K, JIS: 40K, ANSI: 150lb, ANSI: 300lb
  • Material Gehäuse
    Stainless steel, Steel ST37 (coated)
  • Durchmesser
    DN4 ... 600 (other diameters on request)
  • Spannungsversorgung
    24 VAC/ VDC with reverse polarity protection, 230 VAC (50/60 Hz), 110 VAC (60Hz), Battery
  • Elektrischer Anschluss
    Terminal 1 & 2: Analog output 4...20 mA, Terminal 3 & 4: Pulse output / flow switch 1, Terminal 5 & 6: RS485, Terminal 7 & 8: Pulse output / flow switch 2, Terminal 9 & 10: Reset of the volume register, Terminal 11 & 12: Output voltage 16V/100mA (power supply for switching to active current and pulse outputs), Terminal L, N, PE: Power supply
  • Leistungsaufnahme max
    4.6 VA
  • Umgebungstemperatur
    0 ... 55°C
  • Zertifikate
    CE
  • ATEX-Zertifizierung
    none
  • SIL-Level
    none
  • Ursprungsland
    Germany
  • Zolltarifnummer
    90 26 80 20
  • HS Code
    90 26 80
  • Reproduzierbarkeit des Ausgangssignals
    0,2%

Customer Reviews

Based on 3 reviews
100%
(3)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
E
Erik Klein
Fresh water measurement

I use the device with hard rubber casing and remote display. Punctual delivery, simple installation with flange connection and smooth operation ever since.

H
Horst Jedek
Reliable sensor

Have had the device since July and am satisfied. Installation was straightforward and the accuracy is impressive.
Sensor works reliably. Overall, highly recommended for industrial applications.

F
Felix Kungert
Super service & easy installation, device runs reliably

We have been using the device for about 4 weeks to measure the flow in a drinking water pipe (WAZV).
Very professional advice from the seikom team. Device was delivered on time. Installation and IBN went smoothly. Any time again!

Electromagnetic flowmeter FlowGuard® FT410

Electromagnetic flowmeter FlowGuard® FT410

Away €1.083,00

✅ Flow measurement from 0.06 to 12 m/s

✅ Bidirectional measurement with direction detection and empty pipe detection

✅ With pulse output, analog signal (4-20 mA), HART and Modbus connection

✅ Various process connections and linings ideal for your process, with drinking water approval on request

✅ Special versions are also suitable as heat meters or for use in ATEX environments

✅ Optionally available up to protection class IP68 and therefore ideal for industrial use

✅ Manufactured for you and available at short notice within ~3 weeks

Verfügbarkeit

Stromaufnahme

Spezifikation Reaktionszeit (s)

Minimaler Rohrdurchmesser

Messbereich Temperatur Filter

HS Code

90 26 80

Ausgangsleistung min.

Auflösung Feuchtigkeit

Spezifikation Analogausgang

4 ... 20 mA, 2x pulse/flow switch (max. 400 Hz)

Produktart Strömung

Schutzart Sensor

IP65, IP67, IP68

Eintauchtiefe

Genauigkeit des Atmosphärendrucks

Gewicht

Isolationswiderstand

Materialanschlusskopf

Materialsensor

Stainless steel DIN 1.4571, Hastelloy C4, Titanium, Tantalum

Reaktionszeit

Schutzart Gehäuse

Typ des Sensorelements

Umgebungstemperatur

0 ... 55°C

ATEX-Zertifizierung

none

Spezifikation Befestigungsband

Gehäuseabmessungen

Gerätebauart

Compact device, with remote evaluation unit (standard cable length 3 m)

Gerätetyp

Magnetic inductive flow meter

Kabellänge Fühler

Konformität

Material Gehäuse

Stainless steel, Steel ST37 (coated)

Messbereich Temperatur

Messgenauigkeit Temperatur

Produktart Temperatur

Silber Level

Umgebungstemperatur Gerät

Betriebsdruck

Medium

Liquids

Messbereich Druck

Produktart Druck

Prüfzeichen

Schaltdifferenz

Schaltleistung

Schaltpunkt

Betriebsspannung

Digitalausgang

Eigenverbrauch

Messbereich CO₂

Messgenauigkeit relative Feuchtigkeit

Produktart Luftfeuchtigkeit

Reaktionszeitmessung Co.

Spannungsversorgung

24 VAC/ VDC with reverse polarity protection, 230 VAC (50/60 Hz), 110 VAC (60Hz), Battery

Hersteller

Produktart HVAC

Analogsignal

Leistungsaufnahme max

4.6 VA

Maximaler Druck

Anzeige

elektrischer Anschluss

Terminal 1 & 2: Analog output 4...20 mA, Terminal 3 & 4: Pulse output / flow switch 1, Terminal 5 & 6: RS485, Terminal 7 & 8: Pulse output / flow switch 2, Terminal 9 & 10: Reset of the volume register, Terminal 11 & 12: Output voltage 16V/100mA (power supply for switching to active current and pulse outputs), Terminal L, N, PE: Power supply

Betriebstemperatur

Produktart-Füllstand

Spezifikation Relaisausgang

Lastwiderstand

Umgebungsfeuchtigkeit

Umgebungstemperatur Maximal Celsius

Umgebungstemperatur (min. °C)

Druckfestigkeit

PN10, PN16, PN25, PN40, PN64, PN100, JIS: 10K, JIS: 20K, JIS: 40K, ANSI: 150lb, ANSI: 300lb

Medientemperatur

Compact: max. 90°C (depending on version), Remote: max. 150°C (depending on version)

Produktart

Prozessanschluss

Sandwich (PN25 only), Flanged DIN (EN1092) - Carbon or stainless steel, Thread (EN 10226-1) Food grade (DIN 11851 fitting, clamp)

Temperaturgradient

Messwiderstand

Differenzdruck max

Genauigkeit des Ausgangssignals LCD Modbus

Messbereich Strömung

0.06 ... 12m/s, bidirectional measurement, max. (1/200)

Signalausgang

Prozessanschluss 1

Schaltfunktion bei Strömung

Signalanzeige bei Strömung

Signalausgang Strömung

Analogausgang

Hinweise

Mindestschaltleistung

Optimale Auslaufstrecke

Optimale Einlaufstrecke

Reproduzierbarkeit des Ausgangssignals

0,2%

Signalanzeigeschaltung

Strom- und Kontaktbelastbarkeit

Toleranz Spannungsversorgung

Überspannungskategorie

Verschmutzungsklasse

Analogeingang_CO_

Digitaleingang

Messbereich relative Feuchtigkeit

Potentiometer

Potentiometerausgang

Skalenbereich

Analogeingang

Analogeingang_CO2

Einbautiefe

digitale Ausgänge

digitale Eingänge

Fehlereingänge

Umgebungstemperatur1

Farbe

Ausgangssignal

Pulse output, Analog output, Digital output

Leitungsquerschnitt empfohlen

Signalausgang Sensorkurzschluss

Signalausgang Sensorbruch

<3.5 mA

Durchmesser außen

Durchmesser innen

Gewinde

Temperaturbereich

Auskleidung

Durchmesser

DN4 ... 600 (other diameters on request)

Messgenauigkeit Strömung

≤0.5% of the measured value

Einstellbereich

Fühleransprechlänge

Kapillarrohrlänge

Schutzklasse

Material

Messgenauigkeit Druck relativ

Temperaturkompensation

Ursprungsland

Germany

Vakuumfestigkeit

Hysterese

Wiederholbarkeit

Materialkontakt

Berstdruck

Messbereich Atmosphärendruck

Messbereich Druck V2

Kurzschlussschutz

Max Bürde

Verpolungsschutz

Genauigkeit der Messung von VOC

Messbereich VOC

Medienkompatibilität

Überlastdruck

Alarm

Messbereich VOC1

Relaisausgang

Leistung (kW)

Wärmeabgabe

Minimale Belastung

Versorgungsausgang

Kabelgräue

Lagertemperatur

Sicherung

Messgenauigkeit_CO_

Frontabdeckung

Schnittstelle

Stromzufuhr

Wirkungsgrad

Langzeitstabilität

Schaltpunkt voreingestellt

Zolltarifnummer

90 26 80 20

Riemenscheibe

Medientemperatur Max

Medientemperatur min

Show product

Welcome to Shopify Store

I act like: