Sensor F8 250°C
Description
Description
✅ Calorimetric measurement principle – proven measurement technology for high temperatures
✅ Maximum temperature range: -20 to +250°C; can be used up to +400°C with the NLSW®45-6.1 evaluation unit and the F8 400°C sensor
✅ V4A stainless steel (high-temperature resistant) – corrosion-resistant in exhaust gases
✅ Temperature gradients: 20 K/min – stable measurement during temperature changes
✅ Standard immersion depths: 50, 130, 165, 300, 400, 500 mm – others available upon request
✅ Process connection: PG7 with optional reducers (G1/2-inch, M16×1.5, M20×1.5)
✅ Pressure resistance: 10 bar – suitable for industrial high-pressure boilers
✅ IP50 protection rating – designed for aggressive high-temperature environments
✅ Compatible with NLSW®45-6 (up to 250°C) or NLSW®45-6.1 (up to 400°C)
✅ SIL1 variant: F8 SIL1 250°C available for safety-critical applications
✅ Applications: Industrial furnaces, boilers, flue gas measurements, emissions monitoring
✅ German quality: TÜV-Nord type approval according to DIN EN 61010-1
Sensor F8 250°C - 50 / 2,5 is in stock and is sent as soon as it is available again
Delivery time: Available immediately
Technische Zeichnung 3D: Download
Technische Zeichnung 2D: Download
Bedienungsanleitung DE: Download
Bedienungsanleitung EN: Download
specification
specification
-
MediumGases
-
Device typeFlow sensor
-
Device designSensor
-
Flow range0.1 m/s ... 30 m/s
-
Medium temperature-20 ... 250°C
-
Protection class sensorIP50
-
Immersion depth50 mm, 130 mm, 165 mm, 300 mm, 400 mm, 500 mm, Special lengths on request
-
Process connectionPG7, Optional G1/2-inch connection using a reducer
-
Sensor materialStainless Steel 1.4571
-
Pressure resistance10 bar
-
Electrical connectionStandard cable length: 2.5 m, 5 m, Custom cable lengths available upon request
-
Temperature gradient
-
CertificatesCE, Type-tested by TÜV Nord in accordance with DIN EN 61010-1 2011-07
-
ATEX certificationnone
-
SIL levelnone
-
Customs tariff number
-
HS code
Frequently Asked Questions
Warum ist ein Fühler F8 250°C mit dem größten Temperaturbereich notwendig?
Warum ist ein Fühler F8 250°C mit dem größten Temperaturbereich notwendig?
Kann ich F8 in Rauchgasmessungen nach EN 303-5 (Kaminöfen) einsetzen?
Kann ich F8 in Rauchgasmessungen nach EN 303-5 (Kaminöfen) einsetzen?
Was ist der Unterschied zwischen NLSW®45-6 und NLSW®45-6.1?
Was ist der Unterschied zwischen NLSW®45-6 und NLSW®45-6.1?
Ist IP50 Schutzart (statt IP67) ein Problem?
Ist IP50 Schutzart (statt IP67) ein Problem?
Kann ich F8 auch in niedrigen Temperaturen (-20°C) einsetzen?
Kann ich F8 auch in niedrigen Temperaturen (-20°C) einsetzen?
Gibt es eine SIL-Variante von F8 für sicherheitskritische Prozesse?
Gibt es eine SIL-Variante von F8 für sicherheitskritische Prozesse?
Welche Wartung braucht F8 bei Hochtemperatur-Betrieb?
Welche Wartung braucht F8 bei Hochtemperatur-Betrieb?