Evaluation unit air flow monitor NLSW45-3 - Universal flow monitor with switching output, measuring range gases 0.1 ... 30 m/s
Description
Description
✅ Universal air flow monitor with switching output for switch cabinet installation
✅ Type tested by TÜV NORD in accordance with DIN EN 61010-1: 2011-07
✅ Large measuring range, quick and easy commissioning
✅ Exemplary areas of application: Monitoring industrial systems, heating registers, air curtain systems, dampers, fans, HVAC applications
Evaluation unit air flow monitor NLSW45-3 - Universal flow monitor with switching output, measuring range gases 0.1 ... 30 m/s - 230 V AC is in stock and is sent as soon as it is available again

Availability for collection could not be loaded
Technische Zeichnung 3D: Download
Technische Zeichnung 2D: Download
Bedienungsanleitung DE: Download
Bedienungsanleitung EN: Download
specification
specification
-
MediumGases
-
Device typeFlow evaluation unit for switch cabinet installation
-
Flow range0.1 ... 30 m/s
-
Medium temperature-25 ... 120°C
-
DisplayLED (voltage & switching point)
-
Switching pointStepless adjustment (potentiometer)
-
Protection class evaluation unitIP40
-
Special featuresStart-up override 5-60 sec., additional external start-up override
-
Output signalSwitching output
-
Switching output specification1 changer
-
Sensor break output signalRelay drops out
-
Sensor short-circuit output signalRelay drops out
-
Relay output specification1 changer
-
Housing materialPolycarbonate glass fiber reinforced (UL94V-0)
-
MountingDIN rail
-
Power supply24 V AC/DC ±5%, 230 V AC ±6%
-
Electrical connectionTerminal strip
-
Max. power consumption3 VA
-
Recommended cable cross-section2.5 mm²
-
Minimum switching capacity10 mA, 5 V DC
-
Ambient temperature-20 ... 50°C
-
CertificatesCE, Type-tested by TÜV Nord in accordance with DIN EN 61010-1 2011-07
-
ATEX certificationnone
-
SIL levelnone
-
Country of origin
-
Customs tariff number
-
HS code
Häufig gestellte Fragen
Was ist der Unterschied zwischen den NLSW45-3 Versionen?
Was ist der Unterschied zwischen den NLSW45-3 Versionen?
Welche Sensoren sind verfügbar?
Welche Sensoren sind verfügbar?
Was bedeutet die Z/Z-Klemmen-Funktion?
Was bedeutet die Z/Z-Klemmen-Funktion?
Warum ist der NLSW45-3 günstiger als in den SIL-Versionen?
Warum ist der NLSW45-3 günstiger als in den SIL-Versionen?
Welche Einbauhinweise sind zu beachten?
Welche Einbauhinweise sind zu beachten?
Wie wird das Gerät montiert?
Wie wird das Gerät montiert?
Ist eine Kabelverlängerung möglich?
Ist eine Kabelverlängerung möglich?
Was sind typische Anwendungen?
Was sind typische Anwendungen?