Electromagnetic flowmeter FlowGuard® FT420 Ex
Description
Description
✅ Flowmeter for monitoring liquid media
✅ LED display shows flow rate and contact closure
✅ Robust design for industrial environments, IP65 ... IP68 possible
✅ Suitable for ATEX environments
✅ Frequent applications: Chemical industry, water treatment plants, biogas plants, etc.
✅ Available at short notice within 3 weeks
Electromagnetic flowmeter FlowGuard® FT420 Ex - DN15 / Flange / PTFE is in stock and is sent as soon as it is available again

Availability for collection could not be loaded
specification
specification
-
MediumLiquids
-
Device typeMagnetic inductive flow meter
-
Device designCompact device
-
Flow range0.2 ... 12m/s, bidirectional measurement
-
Flow accuracy≤0.5% of the measured value
-
Medium temperature40°C
-
Protection class sensorIP65, IP67, IP68
-
Protection class housingIP65, IP67, IP68
-
Output signalPulse output, Analog output, Frequency output
-
Sensor break output signal<3.5 mA
-
Process connectionSandwich (PN25 only), Flanged DIN (EN1092) - Carbon or stainless steel, Thread (EN 10226-1), Food grade (DIN 11851 fitting, clamp)
-
Housing materialSteel ST37 (coated), Stainless steel flange SS304, Stainless steel flange SS316
-
Sensor materialStainless steel DIN 1.4571, Hastelloy C4, Titanium, Tantalum
-
Pressure resistancePN10, PN16, PN25, PN40, PN64, PN100, JIS: 10K, JIS: 20K, JIS: 40K, ANSI: 150lb, ANSI: 300lb
-
DiameterDN15 ... 200 (other diameters on request)
-
Power supply24 V DC ±15%
-
Electrical connectionAmphenol C016 (7 pin) plug connector for I M2 Ex Mb I and I M1 Ex ia I ma, Sealcon M23 (7 pin) connector for II 1G Ex ia IIC T6 Ga and II 1D Ex ia IIIC T85 °C Da
-
Max. power consumption4.2 VA
-
Ambient temperature0 ... 55°C
-
CertificatesCE
-
ATEX certificationI M1 Ex ia I Ma, II 1G Ex ia IIC T6 Ga, II 2D Ex ia IIIC T85°C Db, none
-
SIL levelnone
-
Country of origin
-
Customs tariff number
-
HS code
-
LiningHard rubber, Soft rubber, Rubber with drinking water approval, PTFE
-
Signal output reproducibility0,2%