Sensor F3

Sku: 50276/50

Description

Sensor for flow monitoring of gases up to 120°C

✅ Measuring range 0.1 to 30.0 m/s

Standard cable length 2.5 m - Optionally extendable up to 50 m

✅ For easy installation and alignment of the sensor in the air flow: Screw-in adapter (available separately)

Special lengths on request available

✅ Depending on the desired output signal to be used with

  • Aevaluation unit NLSW®45-3 (for monitoring an adjustable switching point)
  • Evaluation unit NLSW®75A (for analog signal (4-20 mA & 0-10 V), as well as for monitoring an adjustable switching point)

⚠️ Not suitable for potentially explosive atmospheres (here: Flow sensor F3 Ex insert)

⚠️ If a SIL certification is required: Flow sensor F3 SIL1, F3 SIL2, F3 Ex SIL1 or F3 Ex SIL2 use

Immersion depth
€120,30
Shipment is calculated in the checkout.
Lieferzeit Symbol Delivery time: Available immediately

Technische Zeichnung 3D: Download

Technische Zeichnung 2D: Download

Bedienungsanleitung DE: Download

Bedienungsanleitung EN: Download

specification

  • Medium
    Gases
  • Device type
    Flow sensor
  • Device design
    Sensor
  • Flow range
    0.1 m/s ... 30 m/s
  • Medium temperature
    -25 ... 120°C
  • Protection class sensor
    IP67
  • Immersion depth
    50 mm, 130 mm, 165 mm, 300 mm, 400 mm, 500 mm, Special lengths on request
  • Process connection
    PG7, optional G1/2-inch / G1/4-inch by means of reducer
  • Sensor material
    MS58 nickel-plated, other materials on request (e.g. 1.4571)
  • Pressure resistance
    10 bar
  • Weight
    130 g
  • Electrical connection
    Standard cable length 2.5 m, Special lengths on request 3 x 0.5 mm²
  • Temperature gradient
    30K/min
  • Certificates
    CE, Type-tested by TÜV Nord in accordance with DIN EN 61010-1 2011-07
  • ATEX certification
    none
  • SIL level
    none
  • Country of origin
    Germany
  • Customs tariff number
    90 26 80 20
  • HS code
    90 26 80

Häufig gestellte Fragen

Was ist das kalorimetrische Messprinzip beim F3 Sensor?

Der F3 nutzt das kalorimetrische (thermische) Prinzip: Ein beheiztes Sensorelement wird von der strömenden Luft gekühlt. Die Temperaturdifferenz zwischen beheiztem Element und Medium ist proportional zur Strömungsgeschwindigkeit und ermöglicht präzise Massenluftstrommessung ohne bewegliche Teile.

Welche Eintauchtiefen sind verfügbar?

6 Bauformen: F3/50 (50 mm), F3/130 (130 mm), F3/165 (165 mm), F3/300 (300 mm), F3VA/400 (400 mm), F3VA/500 (500 mm). Empfohlen wird Einschraubadapter (Art. 80404) ab 130 mm für variable Eintauchtiefe und einfache Reinigung.

Welche Prozessanschlüsse sind möglich?

Standard PG7-Gewinde. Optional per Reduzierstück: G1/2-Zoll (Art. 80399), M16×1,5 (Art. 80403), M20×1,5 (Art. 80402). Alternativ Montage per Montageflansch (Art. 79781/10) oder Einschraubadapter (Art. 80404).

Wie wird der F3 Sensor korrekt eingebaut?

Sensor nur über Sechskant einschrauben, einbaulageunabhängig. Kleine Einkerbung am Sensor in Strömungsrichtung ausrichten. Sensorspitze möglichst in Rohrmitte. Mindestens 5×D Einlaufstrecke, 3×D Auslaufstrecke. Bei vertikalen Rohren (<1 m/s) Strömung von unten nach oben bevorzugt.

Ist eine Kabelverlängerung möglich?

Ja, Standardkabel 2,5 m, ist bis 50 m verlängerbar. bitte anfragen.

Welche Materialvarianten gibt es?

Standard: MS58 vernickelt (korrosionsbeständig, wirtschaftlich). Optional: Edelstahl V4A (für aggressive Medien, Pharma, Lebensmittel) ab > 300 mm nur VA möglich. Beide Varianten mit identischer Leistung, IP67, 10 bar Druckfestigkeit.

Wie wird der Sensor gewartet?

1) Sensor demontieren, 2) In handwarmer Seifenlauge ca. 10 Min. einlegen, 3) Mit handwarmem Wasser abspülen, 4) Mindestens 24 Stunden trocknen lassen, 5) In trockenem Zustand montieren, 6) Neuen Abgleich mit Auswerteeinheit vornehmen. Niemals scharfe Werkzeuge verwenden!

Mit welchen Auswerteeinheiten ist der F3 kompatibel?

NLSW®2a (kompakt), NLSW®45-3 (Standard/SIL/ATEX), NLSW®75-A (erweiterte Funktionen). Vertauschen der Anschlüsse führt zu Fehlfunktionen und Beschädigungen – Anschlussplan beachten! nur Passende Ausführungen.

Sensor F3

Away €120,30

Sensor for flow monitoring of gases up to 120°C

✅ Measuring range 0.1 to 30.0 m/s

Standard cable length 2.5 m - Optionally extendable up to 50 m

✅ For easy installation and alignment of the sensor in the air flow: Screw-in adapter (available separately)

Special lengths on request available

✅ Depending on the desired output signal to be used with

⚠️ Not suitable for potentially explosive atmospheres (here: Flow sensor F3 Ex insert)

⚠️ If a SIL certification is required: Flow sensor F3 SIL1, F3 SIL2, F3 Ex SIL1 or F3 Ex SIL2 use

Medium

Gases

Device type

Flow sensor

Device design

Sensor

Temperature range

Temperature accuracy

Flow range

0.1 m/s ... 30 m/s

Flow accuracy

Medium temperature

-25 ... 120°C

Relative pressure range

Relative pressure accuracy

Atmospheric pressure range

Atmospheric pressure accuracy

Measured variable

Differential pressure range

Differential pressure accuracy

VOC range

VOC accuracy

CO₂ range

CO₂ accuracy

Relative humidity range

Relative humidity accuracy

Number of differential pressure ranges

Maximum measuring range limit

Display

Switching point

Protection class evaluation unit

Protection class sensor

IP67

Protection class housing

Special features

Cable length

IK impact resistance rating

Luminous flux

Emergency luminous flux

Efficiency

Light color

Color rendering index CRI

Flicker factor

Power factor

Humidity resolution

Temperature resolution

Max. differential pressure

Adjustment range

product.metafields.custom.messgroesse1

Output signal

Analog output specification

Switching output specification

Digital output specification

Sensor break output signal

Sensor short-circuit output signal

Analog input

Digital input

Relay output specification

Immersion depth

50 mm, 130 mm, 165 mm, 300 mm, 400 mm, 500 mm, Special lengths on request

Process connection

PG7, optional G1/2-inch / G1/4-inch by means of reducer

Housing material

Connection head material

Sensor material

MS58 nickel-plated, other materials on request (e.g. 1.4571)

Pressure resistance

10 bar

Overpressure limit

Weight

130 g

Operating pressure

Housing dimensions

Mounting

Minimum pipe diameter

Fastening strap specification

Burst pressure

Vacuum resistance

Dimensions

Cable gland

Diameter

Installation depth

Front cover material

Sensor response length

Capillary tube length

Max. pressure

Power supply

Electrical connection

Standard cable length 2.5 m, Special lengths on request 3 x 0.5 mm²

Max. power consumption

Power

Recommended cable cross-section

Load resistance

Insulation resistance

Current and contact rating

Response time

Minimum switching capacity

Protection class

Min. output power

Self-consumption

product.metafields.custom.leistung Bürde max.

Max. input current

Measuring resistor

Switching differential

Overvoltage category

Reverse polarity protection

Supply output

Sensor element type

Ambient temperature

Storage temperature

Ambient humidity

Ambient pressure

Temperature compensation

Optimal inlet path

Optimal outlet path

Temperature gradient

30K/min

Certificates

CE, Type-tested by TÜV Nord in accordance with DIN EN 61010-1 2011-07

ATEX certification

none

SIL level

none

Country of origin

Germany

Customs tariff number

90 26 80 20

HS code

90 26 80

Warranty

Service life

Fire protection

Alarm

Lining

Color

Output signal accuracy LCD/Modbus

Manufacturer

Notes

Hysteresis

Conformity

Long-term stability

Material contact

Media compatibility

Emergency light

Certification mark

Signal output reproducibility

Switching function (flow)

Fuse

Wet bulb temperature spec.

Dew point temperature spec.

Absolute humidity spec.

Availability

Pollution degree

Heat dissipation

Repeatability

Permissible air velocity

Internal thread

External thread

Wrench size

Inner diameter

Accessories